Structural Design Assessment Answer
Task:
The figures above show a typical floor plan and section elevation of a three-storied reinforced concrete office building to be constructed at Townsville. Drawing is not to scale. All units are in mm. This is a framed reinforced concrete building monolithically cast with the beams along grids A, B and C supporting the RC floor. The beams transfer the load to the columns rigidly connected to them at their supports. Assume that the thickness of the floor slabs and the roof slab are 200 mm and they all have the same beam layout. Slope of the inaccessible roof (except for maintenance) can be ignored and can be considered as flat. The roof has an overhang of 300 mm all around the building as shown in the fig. above. The ground floor slab is slab-on-ground so the load will be transferred directly to the soil below. Beams along grids 1 and 6 are of 300 mm width x 600 mm deep and support the brick walls completely and the slab as well.
Because of the space issues and to eliminate the differential settlement, combined footings are to be designed. In reality, all the columns of B row, B1 to B6 will be combined to a single footing or A1, B1 and C1 etc. can be combined to a single footing, all the columns of the building will be connected a single raft footing. For the assignment purpose, the design is simplified, so combined footings are to be designed for columns B1 and C1, B2 and C2 etc. All the columns are rigidly connected to footings. All the glass windows are 2000 mm x 1800 mm x 20 mm. The brick masonry wall is 180 mm thick.
Because of the difference in elevation between the ground level where the building will be constructed and the adjacent area, a suitable retaining wall is to be designed to accommodate the step change. The retaining wall is parallel to grid 1 and is only on the left side of the building (not shown in fig.). The wall will retain soil only on one side, i.e. on the side of the building. Because the wall is close to the building, assume that
a part of the building load
is to be carried by the retaining wall. In the absence of exact calculations, assume that the building loads up to Grid 3 will be carried by the retaining wall and this load can be considered as a surcharge load acting on the retaining wall. The height of the wall is the difference between the GL of the building and the GL of the bottom level of the wall, which is provided in Table 1 below. In reality, the calculation is more complicated, things have been simplified for the assignment purpose. If you want to do precise calculation, proceed without any problem. Assume data not supplied, however, explain the reasons of the assumed values.
DESIGN DATA
Concrete characteristic strength, f
c
= Y MPa
Yield strength of reinforcing steel, f
y
= 500 MPa.
Density of RCC, ? = 2500 kg/m
3
.
Glass windows are of unit weight, ? = 2600 kg/m
3
.
Exposure classification: A2.
Take appropriate values of X and Y and other values as appropriate from Table 1 depending on the
last two digits
of your Student ID number. Assume appropriate realistic values for other design data that are not provided.
Assume that a shear wall (not shown in fig.) would carry the lateral wind loading. Ignore this for preliminary design.
All design and detailing should be in accordance with AS 3600 2009 and loading should be in accordance with AS 1170.0, AS1170.1.
Ignore secondary effects.
PROBLEM STATEMENT
Q1. Load estimation
a) Calculate the loadings acting on the columns i) B1 and ii) C1 at the footing level. Use approximate methods (based on codes) for appropriate load combinations OR do a frame analysis using Strand7 as per cl
Q2. Footing design and detailing
a) Design a combined footing (dimensions L, W and D) for columns B1 and C1 ONLY for strength and serviceability requirements. Ensure that the soil pressure distribution below the footing is uniform. Assume that clear cover at the bottom is 75 mm and cover all around is 50 mm.
b) Design the reinforcement required and draw the reinforcement detailing clearly showing at least 2 views
.
Q3. Retaining wall design
a) Calculate all the loads acting on the RC cantilever retaining wall for the height given in Table 1. The backfilled soil is crushed gravel deposit with the properties:
c=0
kPa,
?
= 19,30
o
?
=
kN/m
3
. The subsoil below the base is clay with
c=6
kPa,
?
= 19,30
o
?
=
kN/m
3
with an allowable bearing capacity q
a
= 250 kPa. Neglect the effect of wind and seismic load (if any). Assume clear cover at the bottom of the base is 75 mm and cover all around is 50 mm. Draw a sketch of the wall showing the forces acting on it.
Design the retaining wall for stability and serviceability requirements. (35 marks)
Design the reinforcement required. Drawing showing reinforcement detailing not
required.
This CIV4508: Structural Design Assignment has been solved by our Civil Engineering experts at TVAssignmentHelp. Our Assignment Writing Experts are efficient to provide a fresh solution to this question. We are serving more than 10000+ Students in Australia, UK & US by helping them to score HD in their academics. Our Experts are well trained to follow all marking rubrics & referencing style.
Be it a used or new solution, the quality of the work submitted by our assignment experts remains unhampered. You may continue to expect the same or even better quality with the used and new assignment solution files respectively. Theres one thing to be noticed that you could choose one between the two and acquire an HD either way. You could choose a new assignment solution file to get yourself an exclusive, plagiarism (with free Turnitin file), expert quality assignment or order an old solution file that was considered worthy of the highest distinction.